Search results for "Body Burden"
showing 10 items of 15 documents
Association between toenail scandium levels and risk of acute myocardial infarction in European men: the EURAMIC and Heavy Metals Study
2002
The association between scandium status and risk of acute myocardial infarction (MI) was examined in a multicentre case control study in 10 centres from Europe and Israel. Scandium in toenails was assessed in 684 cases and 724 controls less than 70 years of age. Mean concentrations of toenail scandium were 6.74 micro/kg in cases and 7.75 microg/kg in controls. Scandium among controls, adjusted for age and centre was positively associated with concentrations of lycopene and oleic acid in adipose tissue (P = 0.002 for both nutrients). Pearson correlations adjusted for age and centre were significant (P0.05) between scandium and lycopene (r = 0.08), zinc (r = 0.08), mercury (r = 0.18) and olei…
Mercury exposure and risk of cardiovascular disease: a nested case-control study in the PREDIMED (PREvention with MEDiterranean Diet) study
2017
Background: Substantial evidence suggests that consuming 1-2 servings of fish per week, particularly oily fish (e.g., salmon, herring, sardines) is beneficial for cardiovascular health due to its high n-3 polyunsaturated fatty acid content. However, there is some concern that the mercury content in fish may increase cardiovascular disease risk, but this relationship remains unclear. Methods: The PREDIMED trial included 7477 participants who were at high risk for cardiovascular disease at baseline. In this study, we evaluated associations between mercury exposure, fish consumption and cardiovascular disease. We randomly selected 147 of the 288 cases diagnosed with cardiovascular disease duri…
Frequency of dicentrics and contamination levels in Ukrainian children and adolescents from areas near Chernobyl 20 years after the nuclear plant acc…
2013
International audience; Purpose To survey the possible presence of chromosomal damage and internal contamination in a group of Ukrainian children and adolescents, 20 years after the Chernobyl accident at the Nuclear Power Plant. Materials and methods Cytogenetical procedures were performed according to dicentric assay in 55 Ukrainian children and adolescents (29 boys and 26 girls), living near Chernobyl. In addition, a whole body detector and urinalysis were used to detect internal contamination. Results 36 dicentrics were found in a total of 53,477 metaphases scored in these children, which reflected a frequency of dicentrics below the background level. On the other hand, internal contamin…
Uncertainty on radiation doses estimated by biological and retrospective physical methods
2018
International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…
Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography
2013
Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…
Heavy metal exposure in patients suffering from electromagnetic hypersensitivity
2009
Abstract Background Risks from electromagnetic devices are of considerable concern. Electrohypersensitive (EHS) persons attribute a variety of rather unspecific symptoms to the exposure to electromagnetic fields. The pathophysiology of EHS is unknown and therapy remains a challenge. Objectives Heavy metal load has been discussed as a potential factor in the symptomatology of EHS patients. The main objective of the study was to test the hypothesis of a link between EHS and heavy metal exposure. Methods We measured lead, mercury and cadmium concentrations in the blood of 132 patients ( n = 42 males and n = 90 females) and 101 controls ( n = 34 males and n = 67 females). Results Our result…
REVIEW OF RETROSPECTIVE DOSIMETRY TECHNIQUES FOR EXTERNAL IONISING RADIATION EXPOSURES
2011
The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic re…
Phantom size in brachytherapy source dosimetric studies
2004
An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…
EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD
2004
Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…
Evaluation of Bone Marrow Infiltration in Non-Neuropathic Gaucher Disease Patients with Use of Whole-Body MRI--A Retrospective Data Analysis.
2015
Purpose: To evaluate whole-body magnetic resonance imaging (WB-MRI) for the assessment of bone marrow infiltration in patients with confirmed Gaucher disease type 1 under long-term enzyme replacement therapy (ERT). Materials and Methods: This retrospective data analysis included 38 patients in two subgroups. Group A: 10 females, 9 males, 15 – 29 years, mean age 22 years and Group B: 11 females, 8 males, 29 – 77 years, mean age 49 years, all treated with alglucerase or imiglucerase for at least 12.5 years. Whole-body MRI was carried out in all patients using a standard MRI protocol. Two radiologists assessed all MR images retrospectively with the use of three different MRI score systems: The…